2,378 research outputs found

    Electroweak Results from LEP and SLC and Tests of the Standard Model

    Full text link
    An update of the electroweak measurements at LEP and SLC is presented. These measurements are used to perform precise tests of the Standard Model. A constraint on the Standard Model Higgs mass is obtained when the direct measurements of mtopm_{top} and MWM_W are included in the fit. A combination with the direct Higgs search is also shown.Comment: 8 page

    GePEToS : A Geant4 Monte Carlo simulation package for Positron Emission Tomography

    Full text link
    GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object-Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented : the design optimization of a liquid Xe micro-PET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 micro-PET camera.Comment: 5 pages, 12 figures, submitted to IEEE Transactions on Nuclear Scienc

    Initial-Final-State Interference in the Z line-shape

    Get PDF
    The uncertainty in the determination of the Z line-shape parameters coming from the precision of the calculation of the Initial-State Radiation and Initial--Final-State Interference is 2 10**(-4) for the total cross section sigma zero(had) at the Z peak, 0.15 MeV for the Z mass M Z, and 0.1 MeV for the Z width Gamma Z. Corrections to Initial--Final-State Interference beyond \Order{\alpha^1} are discussed.Comment: 10 pages LaTeX including 2 PostScript figure

    Experimental study of a liquid Xenon PET prototype module

    Get PDF
    A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any parallax effect. This work reports on the performances of the first LXe prototype module, equipped with a position sensitive PMT operating in the VUV range (178 nm).Comment: Proc. of the 7th International Workshops on Radiation Imaging Detectors (IWORID-7), Grenoble, France 4-7 July 200

    The QCD/SM Working Group: Summary Report

    Full text link
    This Report documents the results obtained by the Working Group on Quantum ChromoDynamics and the Standard Model for the Workshop ``Physics at TeV Colliders'', Les Houches, France, 21 May - 1 June 2001. The account of uncertainties in Parton Distribution Functions is reviewed. Progresses in the description of multiparton final states at Next-to-Leading Order and the extension of calculations for precision QCD observables beyond this order are summarized. Various issues concerning the relevance of resummation for observables at TeV colliders is examined. Improvements to algorithms of jet reconstruction are discussed and predictions for diphoton and photon pi-zero production at the LHC are made for kinematic variables of interest regarding searches for a Higgs boson decaying into two photons. Finally, several improvements implemented in Monte-Carlo event generators are documented

    Bounds on the Higgs-Boson Mass in the Presence of Non-Standard Interactions

    Get PDF
    The triviality and vacuum stability bounds on the Higgs-boson mass are revisited in the presence of new interactions parameterized in a model-independent way by an effective lagrangian. When the scale of new physics is below 50 TeV the triviality bound is unchanged but the stability lower bound is increased by 40-60 GeV. Should the Higgs-boson mass be close to its current lower experimental limit, this leads to the possibility of new physics at the scale of a few TeV, even for modest values of the effective lagrangian parameters.Comment: 5 pages, 2 figures, RevTex, submitted to PR

    The variable finesse locking technique

    Get PDF
    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

    Virgo calibration and reconstruction of the gravitational wave strain during VSR1

    Get PDF
    Virgo is a kilometer-length interferometer for gravitational waves detection located near Pisa. Its first science run, VSR1, occured from May to October 2007. The aims of the calibration are to measure the detector sensitivity and to reconstruct the time series of the gravitational wave strain h(t). The absolute length calibration is based on an original non-linear reconstruction of the differential arm length variations in free swinging Michelson configurations. It uses the laser wavelength as length standard. This method is used to calibrate the frequency dependent response of the Virgo mirror actuators and derive the detector in-loop response and sensitivity within ~5%. The principle of the strain reconstruction is highlighted and the h(t) systematic errors are estimated. A photon calibrator is used to check the sign of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz with systematic errors estimated to 6% in amplitude. The phase error is estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.Comment: 8 pages, 8 figures, proceedings of Amaldi 8 conference, to be published in Journal of Physics Conference Series (JPCS). Second release: correct typo
    • …
    corecore